Mavea C500 Purity Water Softener/Filter Only
Description
Overview
PURITY Quell ST C500 filter cartridges are designed for the catering, and vending machines.
- These filter cartridges reduce the carbonate hardness in water and thus prevent calcium deposits behind the appliance.
- Heavy metal ions such as lead and copper, cloudiness, organic pollutants and other odors such as chlorine tastes and odors residue filtered.
- Applications include coffee and espresso machines, vending machines for hot drinks and combi steamers and ovens.
Note: Mavea softeners use Hydrogen Ion exchange NOT Sodium Ion exchange!
C50 | C150 | C300 | C500 | C1100 | |
---|---|---|---|---|---|
PURITY C 0–70% filter head with variable by-pass | |||||
Capacity1 in liters/US gallons with a temporary hardness of 10°dH2/10gpg3 coffee/espresso/vending machines (by-pass setting 40%) |
960 L 254 US gal |
2,408 L 636 US gal |
4,000 L 1,057 US gal |
6,800 L 1,796 US gal |
11,500 L 3,038 US gal |
Capacity1 in liters/US gallons with a carbonate hardness of 10°dH2/10gpg3 combi ovens/coventional ovens (by-pass setting 10%) |
660 L 254 US gal |
1,656 L 636 US gal |
2,750 L 1,057 US gal |
4,675 L 1,796 US gal |
7,906 L 3,038 US gal |
Max. operating pressure | 8.6 bar / 125 psi | ||||
Operating/water temperature | 4°C–30°C / 39.2 - 86°F | ||||
Nominal flow | 60 l/h 15.85 US gallons/h |
100 l/h 26.42 US gallons/h |
|||
Pressure loss at nominal flow | 0.25 baräî邃3.6 psi | 0.5 baräî邃 7.3psi | |||
Dimensions (W/D/H) Filter head including filter cartridge |
119/118/286 mm 4.69/4.65/11.26 inch |
117/104/419 mm 4.6/4.09/16.50 inch |
125/119/466 mm 4.92/4.69/18.35 inch |
144/144/557 mm 5.67/5.67/21.93 inch |
184/184/557 mm 7.24/7.24/21.93 inch |
Weight (dry/wet) |
1.0 / 1.6 kg 2.2/3.5 lbs | 1.8 / 2.8 kg 3.7/5.5 lbs | 2.8 / 4.2 kg 6.2/9.2 lbs | 4.6 / 6.9 kg 10.1/15.2 lbs | 7.7 / 12.5 kg 16.9/27.5 lbs |
Connections | G 3/8" BSP or 3/8" 18 NPT | ||||
Operating position | Horizontal or vertical | ||||
Chlorine reduction |
The MAVEA PURITY water filter system has been tested according to NSF/ANSI 42 for reduction of chlorine. While testing was performed under standard laboratory conditions, actual performance of the system may vary. | ||||
Average influent concentration | 2.1 mg/L | ||||
Maximum effluent concentration | 0.34 mg/L | 0.31 mg/L | |||
Minimum percent removal | 83.6% | 85.2% | |||
Average effluent concentration | 0.21 mg/L | 0.25mg/L | |||
Average percent removal | 91.4% | 88.6% | |||
Rated service flow (gpm) | 0.25 US gallons/min | 0.44 US gallons/min |
Note: Head not included
Questions & Answers
Customer Reviews (1)
I think this is the
Reviewed on 12/10/2020 by Lorne W.
Was This Review Helpful?